Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,6A,220V AC coil,50Hz,1NC auxiliary contact
0.00ريال
Product Code: LC1E0601M5
Availability: In Stock
Viewed 794 times
Categories
Cart
Account
Search
Recent View
Go to Top
All Categories
×
- Training
- Industrial Automation and Control
-
Low voltage protection devices
-
Motor protection devices
- Contactors & Reversing Contactors - EasyPact TVS
- Contactors & Reversing Contactors - TeSys D
- Contactors & Reversing Contactors - TeSys D capacitor
- Contactors & Reversing Contactors - TeSys F
- Contactors & Reversing Contactors - TeSys Giga
- Contactors & Reversing Contactors - TeSys K
- Contactors & Reversing Contactors - TeSys LE
- Electronic Over Current Relays - Easy TeSys Protect
- Electronic Overload Relays - EOCR
- Motor management system - TeSys island
- Motor protection circuit breakers - Easy TeSys Power GZ
- Motor protection circuit breakers - TeSys GV2
- Motor protection circuit breakers - TeSys GV3
- Motor protection circuit breakers - TeSys GV4
- Thermal Overload Relays - TeSys Giga
- Thermal Overload Relays - TeSys LR9
- Thermal Overload Relays - TeSys LRD
- Relays and industrial accessories
-
Circuit Breakers and Switches
- Air Circuit Breakers - EasyPact MVS
- Air Circuit Breakers - MasterPact MTZ
- Air Circuit Breakers - MasterPact NW
- Miniature Circuit Breakers - Acti 9 C120
- Miniature Circuit Breakers - Acti 9 iC60
- Miniature Circuit Breakers - Acti 9 iK60
- Miniature Circuit Breakers - Residental Domae
- Miniature Circuit Breakers - Residental Resi9
- Molded Case Circuit Breakers - ComPacT INS
- Molded Case Circuit Breakers - ComPacT NS
- Molded Case Circuit Breakers - ComPacT NSX
- Molded Case Circuit Breakers - Easy CVS
- Molded Case Circuit Breakers - Easy GoPact
- Molded Case Circuit Breakers - Easy GoPact MTS
- Residual current devices - Acti 9 iC60 RCBO
- Residual current devices - Acti 9 iID RCCB
- Residual current devices - Vigi for iC60
- Power Quality and Power Factor Correction
-
Motor protection devices
-
Power supplies & Energy monitoring system
-
Energy meters & supplies
- Advanced metering
- Current Transformers
- EasyLogic DM6000H series VAF PF meters
- EasyLogic PM2000 Power Meters
- Industrial Power supplies - (ABLM / ABLS / ABL8)
- PowerLogic PM3000 Power Meters
- PowerLogic PM5000 Power Meters
- Single phase power supplies - Easy Modicon ABL2
- Temperature controller
- Transformers - Modicon ABT7, ABL6
-
Energy meters & supplies
- Control station & joysticks
- Secure Power
- Enclosures
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
EasyPact TVS contactor 3 poles for motor applications up to 6A 2.2kW@440V. It provides a 220V 50Hz AC coil, 1NC built-in auxiliary contacts, power and control connections by screw clamp terminals. 45mm width for standard operating rates up to 1800 cycles per hour. It procures standard reliability and durability with 1.4 Mcycles electrical durability AC-3 and 10 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).
Item specifics
-
Main
- Contactor application Motor control Resistive load
- Device short name LC1E
- Poles description 3P
- Range Easy TeSys
- Utilisation category AC-3 AC-3e AC-1
- [Ie] rated operational current 6 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 6 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 20 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
- [Uc] control circuit voltage 220 V AC 50 Hz
- [Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
- Range of product Easy TeSys Control
- Product or component type Contactor
-
Complementary
- Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 12 A gG at <= 690 V coordination type 1 for power circuit
- Auxiliary contact composition 1 NC
- Average impedance 2.5 mOhm - Ith 20 A 50 Hz for power circuit
- Connections - terminals Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
- Control circuit type AC at 50 Hz
- Control circuit voltage limits 0.85...1.1 Uc (-5…55 °C):operational 50 Hz 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
- Electrical durability 1400000 cycles AC-3 150000 cycles AC-1
- Heat dissipation 2…3 W for control circuit
- Hold-in power consumption in VA 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
- Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C)
- Insulation resistance > 10 MOhm for control circuit
- Irms rated making capacity 60 A at 440 V AC for power circuit conforming to IEC 60947-4-1
- Maximum operating rate 1800 cyc/h 60 °C
- Mechanical durability 10000000 cycles
- Minimum switching current 5 mA for control circuit
- Minimum switching voltage 17 V for control circuit
- Motor power kW 1.1 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...400 V AC 50/60 Hz 2.2 kW at 415 V AC 50/60 Hz 2.2 kW at 440 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
- Mounting support DIN rail Plate
- Non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact
- Operating time 12...22 ms on closing 4...19 ms on opening
- Overvoltage category III
- Pole contact composition 3 NO
- Pollution degree 3
- Power dissipation per pole 0.09 W AC-3 1 W AC-1
- Rated breaking capacity 48 A at 440 V for power circuit conforming to IEC 60947
- Tightening torque Power circuit: 1.2 N.m Control circuit: 1.2 N.m
- [Icw] rated short-time withstand current 80 A 40 °C - 10 s for power circuit 45 A 40 °C - 60 s for power circuit 20 A 40 °C - 600 s for power circuit
- [Ith] conventional free air thermal current 20 A (at 55 °C) for power circuit
- [Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
- [Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
-
Environment
- Depth 80 mm
- Fire resistance 850 °C conforming to IEC 60695-2-1
- Height 74 mm
- IP degree of protection IP2X conforming to IEC 60529
- Mechanical robustness Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
- Net weight 0.3 kg
- Operating altitude 3000 m without derating
- Permissible ambient air temperature around the device -20…70 °C at Uc -60…80 °C storage -5…55 °C operation
- Product certifications CE EAC
- protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30
- Standards IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1
- Width 45 mm
-
Packing Units
- Number of Units in Package 1 1
- Number of Units in Package 2 36
- Package 1 Height 4.900 cm
- Package 1 Length 8.700 cm
- Package 1 Weight 341.200 g
- Package 1 Width 7.800 cm
- Package 2 Height 15.000 cm
- Package 2 Length 40.000 cm
- Package 2 Weight 12.843 kg
- Package 2 Width 30.000 cm
- Unit Type of Package 1 PCE
- Unit Type of Package 2 S02
-
Contractual warranty
- Warranty 18 months